Welcome to TG WasteWater
The SJE PumpMaster® pump switch is designed to directly control pumps up to 3/4 HP at 120 VAC and 2 HP at 230 VAC in potable water, water and sewage applications.
This is the "Pump Up" version. meaning the pump is turned off when the float is up or floating. Also known as normally closed
The SJE PumpMaster® pump switch is not sensitive to rotation or turbulence, allowing it to be used in both calm and turbulent applications.
U.S. Patent No. 5,087,801 and 5,142,108
Features:
Specifications:
CABLE:
Flexible 14 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE)
FLOAT:
7.75 cm diameter x 9.04 cm long (3.05 inches diameter x 3.56 inches long) high impact, corrosion resistance, PVC housing for use in sewage and water up to 60oC (140oF)
ELECTRICAL:
120 VAC 50/50 Hz Single Phase:
Maximum Pump Running Current: 15 amps
Maximum Pump Starting Current: 85 amps
Recommended Pump HP: 560 W (3/4 HP) or less
230 VAC 50/50 Hz Single Phase:
Maximum Pump Running Current: 15 amps
Maximum Pump Starting Current: 85 amps
Recommended Pump HP: 1492 W (1 HP) or less
NOTE: This switch must be used with pumps that provide integral thermal overload protection.
Manufacturer | SJE Rhombus |
---|---|
Attachment |
![]() |
Attachment |
![]() |